Sonatest Masterscan MS380 Ultrasonic Flaw Detector

  • $5,800.00
  • Sonatest Masterscan MS380 Ultrasonic Flaw Detector


    The MS380 has exceptional near surface resolution and advanced DAC/AVG sizing. It has a high performance 450V pulser for attenuative materials.

    Features:

    • Exceptional near surface resolution
    • Advanced DAC/AVG sizing
    • High performance 450V pulser for attenuative materials
    • Minimum range 1 mm, maximum 20 m
    • Programmable pulser with ActiveEdge
    • Interface trigger for water path compensation
    • 5 Khz PRF, interface trigger (IFT) and back wall echo attenuation (BEA); proportional outputs and alarms update at teh PRF;  so high speed testing is easily handled, and full remote control via USB interface provides fast set up changes

     
    Specifications :

    • Test Range:  0-1mm (0.05") up to 1-20000mm (800") at steel velocity.  Variable in 1, 2, 5 sequence or continuously in 1mm (0.05") increments.  Also from 1 to 5000 micro s.
    • Velocity:  256 to 16000m/s, continuously variable
    • Probe Zero:  0 to 999,999 micro s, continuously variable
    • Delay: Calibrated delay from 0-20000mm in 0.05mm steps at steel velocity (0-400" in  0.002 " steps) 0 to 110dB.  Adjustable in 0.1, 0.5, 1, 2, 6, 10, 14 and 20dB steps
    • Pulser Voltage: 100V - 350V (450V MS300) square wave pulser.  Pulse width from spike to 2000ns duration - rise/fall times < 5ns into 50 ohm:  Width adjustment in 2% of nominal width, minimum 1 ns maximum 40 ns.
    • Pulser Repetition Freq:  Selectable 5 to 5000Hz
    • Screen Update Rate:  60Hz (NTSC Mode); 50 Hz (PAL Mode)
    • Rectification:  Full wave, positive or negative halfwave and unrectified rf
    • Frequency Range:  6 narrow bands centred at 0.5, 1, 2.25, 5, 10 and 15 MHz.  Broad band at 2 to 22MHz (-6dB) and 1 to 35 MHz (-20dB)
    • System Linearity:  1 % Full Screen Height (FSH).
    • Amplifier Accuracy +/-0.1dB. Horizontal =/- 0.4 % Full Screen Width (FSW).
    • Reject:  80% linear reject.  LED warning light
    • Units:  Metric (mm), inch (in) or time (micro s)
    • Display:  Colour Transflective  TFT:  Display area 111.4 x 83.5mm (4.39 x 3.29") 320 x 240 pixels.  A-Scan Area 255 x 200 pixels (315 x 200 expanded), 8 colour options and variable brightmess.
    • A-Scan Memory:  Maximum of 800 waveforms
    • Panel Memory:  100 stores for retaining calibrations
    • Thickness Logging:  Storage for 8000 thckness readings
    • AGC:  Sets selected echo to a user defined level (10-90%)
    • DAC:  Defined by up to 10 points and digitally drawn on screen. DAC curves meet requirements of EN1714, JIS, and ASME selectable between -2, -6, -10, -12, and -14dB.
    • AWS:  Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
    • API:  Automatic defect sizing in accordance with API 5UE
    • AVG/DGS:  Automatic defect sizing using probe data
    • TCG:  40 dB dynamic range, 30dB per micro sec; up to 10 points for curve definition
    • Auto-Cal:  Automatic calibration with 2 echoes
    • Reference Waveform:  Recalled waveform can be shown in a different colour to live waveform for direct comparison
    • Display Freeze:  Holds current waveform on screen
    • Peak Memory:  For echo-dynamic pattern capture
    • Outputs:  Full bi-directional serial interface.  Composite video, PAL or NTSC compatibility, Analogue proportional outputs programmable to distance or ampliltlude of signal in the gate.  Transmitter sync output front USB
    • Power Supply:  Lithium Ion battery pack 14.4 V, 5.0 A-h, gives up to 16 hrs duration from a fully charged pack. Recharge time 3-4 hrs.  Mains pack option.
    • Dimensions:  255 x 145 x 145mm (10 x 5.7 x 5.7")
    • Weight:  2.5 kg (5.5lbs) w/ Li-Ion cells.

    • Brands Sonatest
    • Product Code: Sonatest Masterscan MS380
    • Availability: In Stock

    Sonatest Masterscan MS380 Ultrasonic Flaw Detector


    The MS380 has exceptional near surface resolution and advanced DAC/AVG sizing. It has a high performance 450V pulser for attenuative materials.

    Features:

    • Exceptional near surface resolution
    • Advanced DAC/AVG sizing
    • High performance 450V pulser for attenuative materials
    • Minimum range 1 mm, maximum 20 m
    • Programmable pulser with ActiveEdge
    • Interface trigger for water path compensation
    • 5 Khz PRF, interface trigger (IFT) and back wall echo attenuation (BEA); proportional outputs and alarms update at teh PRF;  so high speed testing is easily handled, and full remote control via USB interface provides fast set up changes

     
    Specifications :

    • Test Range:  0-1mm (0.05") up to 1-20000mm (800") at steel velocity.  Variable in 1, 2, 5 sequence or continuously in 1mm (0.05") increments.  Also from 1 to 5000 micro s.
    • Velocity:  256 to 16000m/s, continuously variable
    • Probe Zero:  0 to 999,999 micro s, continuously variable
    • Delay: Calibrated delay from 0-20000mm in 0.05mm steps at steel velocity (0-400" in  0.002 " steps) 0 to 110dB.  Adjustable in 0.1, 0.5, 1, 2, 6, 10, 14 and 20dB steps
    • Pulser Voltage: 100V - 350V (450V MS300) square wave pulser.  Pulse width from spike to 2000ns duration - rise/fall times < 5ns into 50 ohm:  Width adjustment in 2% of nominal width, minimum 1 ns maximum 40 ns.
    • Pulser Repetition Freq:  Selectable 5 to 5000Hz
    • Screen Update Rate:  60Hz (NTSC Mode); 50 Hz (PAL Mode)
    • Rectification:  Full wave, positive or negative halfwave and unrectified rf
    • Frequency Range:  6 narrow bands centred at 0.5, 1, 2.25, 5, 10 and 15 MHz.  Broad band at 2 to 22MHz (-6dB) and 1 to 35 MHz (-20dB)
    • System Linearity:  1 % Full Screen Height (FSH).
    • Amplifier Accuracy +/-0.1dB. Horizontal =/- 0.4 % Full Screen Width (FSW).
    • Reject:  80% linear reject.  LED warning light
    • Units:  Metric (mm), inch (in) or time (micro s)
    • Display:  Colour Transflective  TFT:  Display area 111.4 x 83.5mm (4.39 x 3.29") 320 x 240 pixels.  A-Scan Area 255 x 200 pixels (315 x 200 expanded), 8 colour options and variable brightmess.
    • A-Scan Memory:  Maximum of 800 waveforms
    • Panel Memory:  100 stores for retaining calibrations
    • Thickness Logging:  Storage for 8000 thckness readings
    • AGC:  Sets selected echo to a user defined level (10-90%)
    • DAC:  Defined by up to 10 points and digitally drawn on screen. DAC curves meet requirements of EN1714, JIS, and ASME selectable between -2, -6, -10, -12, and -14dB.
    • AWS:  Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
    • API:  Automatic defect sizing in accordance with API 5UE
    • AVG/DGS:  Automatic defect sizing using probe data
    • TCG:  40 dB dynamic range, 30dB per micro sec; up to 10 points for curve definition
    • Auto-Cal:  Automatic calibration with 2 echoes
    • Reference Waveform:  Recalled waveform can be shown in a different colour to live waveform for direct comparison
    • Display Freeze:  Holds current waveform on screen
    • Peak Memory:  For echo-dynamic pattern capture
    • Outputs:  Full bi-directional serial interface.  Composite video, PAL or NTSC compatibility, Analogue proportional outputs programmable to distance or ampliltlude of signal in the gate.  Transmitter sync output front USB
    • Power Supply:  Lithium Ion battery pack 14.4 V, 5.0 A-h, gives up to 16 hrs duration from a fully charged pack. Recharge time 3-4 hrs.  Mains pack option.
    • Dimensions:  255 x 145 x 145mm (10 x 5.7 x 5.7")
    • Weight:  2.5 kg (5.5lbs) w/ Li-Ion cells.

    Write a review

    Note: HTML is not translated!
        Bad           Good